---
title: CI-710s Auto Integration Time
description: CI-710s Auto Integration Time
---

[Skip to content](https://knowledgebase.cid-inc.com/ci-710s-auto-integration-time#main-content)

English

Show submenu for translations

[![CID green](https://knowledgebase.cid-inc.com/hs-fs/hubfs/CID%20green.png?width=350&height=77&name=CID%20green.png)](https://knowledgebase.cid-inc.com/?hsLang=en)

Open main navigation

Close main navigation

- English
  
  Show submenu for translations
- [Submit a Support Ticket](https://cid-inc.com/plant-science-tools/leaf-area-measurement/ci-110-plant-canopy-imager/support/#SubmitaTicket)

[Submit a Support Ticket](https://cid-inc.com/plant-science-tools/leaf-area-measurement/ci-110-plant-canopy-imager/support/#SubmitaTicket)

 How can we help you?

- There are no suggestions because the search field is empty.

1. [CID Knowledge Base](https://knowledgebase.cid-inc.com/?hsLang=en)
2. [Leaf Analysis CI-202/203/710s](https://knowledgebase.cid-inc.com/leaf-analysis-ci-202-203-710s?hsLang=en)
3. [CI-710s SpectraVue Leaf Spectrometer](https://knowledgebase.cid-inc.com/leaf-analysis-ci-202-203-710s?hsLang=en#ci-710s-spectravue-leaf-spectrometer)

# CI-710s Auto Integration Time

## Auto Integration Time detection mode will automatically increase or decrease the integration time to find 90% saturation.

Integration Time is the duration the detector captures light. This can range from 0.03ms up to 60,000ms. The automatic detection mode will automatically increase or decrease the integration time to find 90% saturation. The CI-710S has a feature that allows the user to set the integration time to “Automatic" or "Manual" integration time. When in Auto mode, the CI-710S will search and set the integration time automatically during both calibration and when performing measurements.

- [Root Analysis](https://knowledgebase.cid-inc.com/root-analysis?hsLang=en#main-content)

    - [CI-602 Narrow Gauge Root Imager](https://knowledgebase.cid-inc.com/root-analysis?hsLang=en#ci-602-narrow-gauge-root-imager)
    - [CI-600 In-Situ Root Imager](https://knowledgebase.cid-inc.com/root-analysis?hsLang=en#ci-600-in-situ-root-imager)
- [Canopy Analysis CI-110P](https://knowledgebase.cid-inc.com/canopy-analysis-ci-110p?hsLang=en#main-content)

    - [CI-110 Plant Canopy Imager](https://knowledgebase.cid-inc.com/canopy-analysis-ci-110p?hsLang=en#ci-110-plant-canopy-imager)
- [Photosynthesis Analysis CI-340](https://knowledgebase.cid-inc.com/photosynthesis-analysis-ci-340?hsLang=en#main-content)

    - [CI-340 Handheld Photosynthesis System](https://knowledgebase.cid-inc.com/photosynthesis-analysis-ci-340?hsLang=en#ci-340-handheld-photosynthesis-system)
- [Leaf Analysis CI-202/203/710s](https://knowledgebase.cid-inc.com/leaf-analysis-ci-202-203-710s?hsLang=en#main-content)

    - [CI-710s SpectraVue Leaf Spectrometer](https://knowledgebase.cid-inc.com/leaf-analysis-ci-202-203-710s?hsLang=en#ci-710s-spectravue-leaf-spectrometer)
    - [CI-203 Handheld Laser Leaf Area Meter](https://knowledgebase.cid-inc.com/leaf-analysis-ci-202-203-710s?hsLang=en#ci-203-handheld-laser-leaf-area-meter)
    - [CI-202 Portable Laser Leaf Area Meter](https://knowledgebase.cid-inc.com/leaf-analysis-ci-202-203-710s?hsLang=en#ci-202-portable-laser-leaf-area-meter)
- [Software](https://knowledgebase.cid-inc.com/software?hsLang=en#main-content)

    - [Rootsnap!](https://knowledgebase.cid-inc.com/software?hsLang=en#rootsnap)

[![felix logo 8-15-2019 transparent-1](https://knowledgebase.cid-inc.com/hs-fs/hubfs/felix%20logo%208-15-2019%20transparent-1.png?width=150&height=92&name=felix%20logo%208-15-2019%20transparent-1.png "felix logo 8-15-2019 transparent-1")](https://knowledgebase.cid-inc.com/?hsLang=en)

123 Waverly Pl., Boston, MA 02135

[mailto:sales@cid-inc.com](mailto:sales@cid-inc.com)

Copyright © 2024, CID Bio-Science